Explore HT
Gene
CACNA1C
Uniprot
Q13936
Protein
Voltage-dependent L-type calcium channel subunit alpha-1C
See alternative names Voltage-gated calcium channel subunit alpha Cav1.2,
Calcium channel, L type, alpha-1 polypeptide, isoform 1, cardiac muscle
Uniprot Function Description
Pore-forming, alpha-1C subunit of the voltage-gated calcium channel that gives rise to L-type calcium currents (PubMed:8392192, PubMed:7737988, PubMed:9087614, PubMed:9013606, PubMed:9607315, PubMed:12176756, PubMed:17071743, PubMed:11741969, PubMed:8099908, PubMed:12181424, PubMed:29078335, PubMed:29742403, PubMed:16299511, PubMed:20953164, PubMed:15454078, PubMed:15863612, PubMed:17224476, PubMed:24728418, PubMed:26253506, PubMed:27218670, PubMed:23677916). Mediates influx of calcium ions into the cytoplasm, and thereby triggers calcium release from the sarcoplasm (By similarity). Plays an important role in excitation-contraction coupling in the heart. Required for normal heart development and normal regulation of heart rhythm (PubMed:15454078, PubMed:15863612, PubMed:17224476, PubMed:24728418, PubMed:26253506). Required for normal contraction of smooth muscle cells in blood vessels and in the intestine. Essential for normal blood pressure regulation via its role in the contraction of arterial smooth muscle cells (PubMed:28119464). Long-lasting (L-type) calcium channels belong to the 'high-voltage activated' (HVA) group (Probable).
(Microbial infection) Acts as a receptor for Influenzavirus (PubMed:29779930). May play a critical role in allowing virus entry when sialylated and expressed on lung tissues (PubMed:29779930).
Sample type
Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.
Precision
Precision (repeatability) is calculated from linearized NPX values over LOD.
Analytical measuring range
The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.
Dilution factor
For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.
Biomarker Validation Data
Additional validation data, as well as a more detailed description of how the Olink panels are quality controlled can be found in our Data Validation documents – go to Document download center