Uniprot
Q13936

Protein
Voltage-dependent L-type calcium channel subunit alpha-1C

See alternative names Voltage-gated calcium channel subunit alpha Cav1.2,
Calcium channel, L type, alpha-1 polypeptide, isoform 1, cardiac muscle

Uniprot Function Description

Pore-forming, alpha-1C subunit of the voltage-gated calcium channel that gives rise to L-type calcium currents (PubMed:8392192, PubMed:7737988, PubMed:9087614, PubMed:9013606, PubMed:9607315, PubMed:12176756, PubMed:17071743, PubMed:11741969, PubMed:8099908, PubMed:12181424, PubMed:29078335, PubMed:29742403, PubMed:16299511, PubMed:20953164, PubMed:15454078, PubMed:15863612, PubMed:17224476, PubMed:24728418, PubMed:26253506, PubMed:27218670, PubMed:23677916). Mediates influx of calcium ions into the cytoplasm, and thereby triggers calcium release from the sarcoplasm (By similarity). Plays an important role in excitation-contraction coupling in the heart. Required for normal heart development and normal regulation of heart rhythm (PubMed:15454078, PubMed:15863612, PubMed:17224476, PubMed:24728418, PubMed:26253506). Required for normal contraction of smooth muscle cells in blood vessels and in the intestine. Essential for normal blood pressure regulation via its role in the contraction of arterial smooth muscle cells (PubMed:28119464). Long-lasting (L-type) calcium channels belong to the 'high-voltage activated' (HVA) group (Probable).

(Microbial infection) Acts as a receptor for Influenzavirus (PubMed:29779930). May play a critical role in allowing virus entry when sialylated and expressed on lung tissues (PubMed:29779930).

Sample type

Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.

Precision

Precision (repeatability) is calculated from linearized NPX values over LOD.

Within run precision Coefficient of Variation (CV)
N/A

Analytical measuring range

The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.

LOD (NPX)
2.1
Hooked
Yes
Hook (NPX)
12.2

Dilution factor

For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.

Dilution factor
1:1

Biomarker Validation Data

Additional validation data, as well as a more detailed description of how the Olink panels are quality controlled can be found in our Data Validation documents – go to Document download center