Gene
SLC44A4

Uniprot
Q53GD3

Protein
Choline transporter-like protein 4

See alternative names Solute carrier family 44 member 4,
Thiamine pyrophosphate transporter 1

Uniprot Function Description

Choline transporter that plays a role in the choline-acetylcholine system and is required to the efferent innervation of hair cells in the olivocochlear bundle for the maintenance of physiological function of outer hair cells and the protection of hair cells from acoustic injury (By similarity) (PubMed:23651124, PubMed:28013291). Also described as a thiamine pyrophosphate transporter in colon, may mediate the absorption of microbiota-generated thiamine pyrophosphate and contribute to host thiamine (vitamin B1) homeostasis (PubMed:24379411).

Has also thiamine pyrophosphate transporter activity.

Sample type

Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.

Precision

Precision (repeatability) is calculated from linearized NPX values over LOD.

Within run precision Coefficient of Variation (CV)
N/A

Analytical measuring range

The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.

LOD (NPX)
1.2
Hooked
Yes
Hook (NPX)
8.8

Dilution factor

For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.

Dilution factor
1:1