Gene
GBA3

Uniprot
Q9H227

Protein
Cytosolic beta-glucosidase

See alternative names Cytosolic beta-glucosidase-like protein 1,
Cytosolic galactosylceramidase,
Cytosolic glucosylceramidase,
Cytosolic glycosylceramidase,
Glucosidase beta acid 3,
Glucosylceramidase beta 3,
Klotho-related protein

Uniprot Function Description

Neutral cytosolic beta-glycosidase with a broad substrate specificity that could play a role in the catabolism of glycosylceramides (PubMed:11389701, PubMed:11784319, PubMed:20728381, PubMed:26724485, PubMed:17595169, PubMed:33361282). Has a significant glucosylceramidase activity in vitro (PubMed:26724485, PubMed:17595169). However, that activity is relatively low and its significance in vivo is not clear (PubMed:26724485, PubMed:17595169, PubMed:20728381). Hydrolyzes galactosylceramides/GalCers, glucosylsphingosines/GlcSphs and galactosylsphingosines/GalSphs (PubMed:17595169). However, the in vivo relevance of these activities is unclear (PubMed:17595169). It can also hydrolyze a broad variety of dietary glycosides including phytoestrogens, flavonols, flavones, flavanones and cyanogens in vitro and could therefore play a role in the metabolism of xenobiotics (PubMed:11784319). Possesses transxylosylase activity in vitro using xylosylated ceramides/XylCers (such as beta-D-xylosyl-(1<->1')-N-acylsphing-4-enine) as xylosyl donors and cholesterol as acceptor (PubMed:33361282). Could also play a role in the catabolism of cytosolic sialyl free N-glycans (PubMed:26193330).

Sample type

Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.

Precision

Precision (repeatability) is calculated from linearized NPX values over LOD.

Within run precision Coefficient of Variation (CV)
N/A

Analytical measuring range

The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.

LOD (NPX)
0.3
Hooked
Yes
Hook (NPX)
11.4

Dilution factor

For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.

Dilution factor
1:1

Biomarker Validation Data

Additional validation data, as well as a more detailed description of how the Olink panels are quality controlled can be found in our Data Validation documents – go to Document download center