Gene
RNF135

Uniprot
Q8IUD6

Protein
E3 ubiquitin-protein ligase RNF135

See alternative names RIG-I E3 ubiquitin ligase,
RING finger protein 135,
RING finger protein leading to RIG-I activation,
RING-type E3 ubiquitin transferase RNF135

Uniprot Function Description

E2-dependent E3 ubiquitin-protein ligase that functions as a RIGI coreceptor in the sensing of viral RNAs in cell cytoplasm and the activation of the antiviral innate immune response (PubMed:19017631, PubMed:19484123, PubMed:21147464, PubMed:23950712, PubMed:28469175, PubMed:31006531). Together with the UBE2D3, UBE2N and UB2V1 E2 ligases, catalyzes the 'Lys-63'-linked polyubiquitination of RIGI oligomerized on viral RNAs, an essential step in the activation of the RIG-I signaling pathway (PubMed:19017631, PubMed:21147464, PubMed:28469175, PubMed:31006531). Through a ubiquitin-independent parallel mechanism, which consists in bridging RIGI filaments forming on longer viral RNAs, further activates the RIG-I signaling pathway (PubMed:31006531). This second mechanism that synergizes with the ubiquitin-dependent one would thereby allow an RNA length-dependent regulation of the RIG-I signaling pathway (Probable). Associated with the E2 ligase UBE2N, also constitutively synthesizes unanchored 'Lys-63'-linked polyubiquitin chains that may also activate the RIG-I signaling pathway (PubMed:28469175, PubMed:31006531).

Sample type

Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.

Precision

Precision (repeatability) is calculated from linearized NPX values over LOD.

Within run precision Coefficient of Variation (CV)
N/A

Analytical measuring range

The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.

LOD (NPX)
1.7
Hooked
Yes
Hook (NPX)
11.7

Dilution factor

For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.

Dilution factor
1:1

Biomarker Validation Data

Additional validation data, as well as a more detailed description of how the Olink panels are quality controlled can be found in our Data Validation documents – go to Document download center