GBA1
Uniprot
P04062
Protein
Lysosomal acid glucosylceramidase
See alternative names Imiglucerase,
D-glucosyl-N-acylsphingosine glucohydrolase,
Cholesterol glucosyltransferase,
Beta-glucocerebrosidase,
Alglucerase,
Acid beta-glucosidase,
Cholesteryl-beta-glucosidase
Uniprot Function Description
Glucosylceramidase that catalyzes, within the lysosomal compartment, the hydrolysis of glucosylceramide/GlcCer into free ceramide and glucose (PubMed:9201993, PubMed:24211208, PubMed:15916907). Thereby, plays a central role in the degradation of complex lipids and the turnover of cellular membranes (PubMed:27378698). Through the production of ceramides, participates in the PKC-activated salvage pathway of ceramide formation (PubMed:19279011). Also plays a role in cholesterol metabolism (PubMed:24211208, PubMed:26724485). May either catalyze the glucosylation of cholesterol, through a transglucosylation reaction that transfers glucose from glucosylceramide to cholesterol (PubMed:24211208, PubMed:26724485). The short chain saturated C8:0-GlcCer and the mono-unsaturated C18:0-GlcCer being the most effective glucose donors for that transglucosylation reaction (PubMed:24211208). Under specific conditions, may alternatively catalyze the reverse reaction, transferring glucose from cholesteryl-beta-D-glucoside to ceramide (PubMed:26724485). Finally, may also hydrolyze cholesteryl-beta-D-glucoside to produce D-glucose and cholesterol (PubMed:24211208, PubMed:26724485).
Sample type
Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.
Precision
Precision (repeatability) is calculated from linearized NPX values over LOD.
Analytical measuring range
The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.
Dilution factor
For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.