Phospholipase A2 group XV

See alternative names 1-O-acylceramide synthase,
Lysosomal phospholipase A2,
Lysophospholipase 3,
LCAT-like lysophospholipase,
Group XV phospholipase A2

Uniprot Function Description

Has transacylase and calcium-independent phospholipase A2 activity (PubMed:20410020, PubMed:23958596). Catalyzes the formation of 1-O-acyl-N-acetylsphingosine and the concomitant release of a lyso-phospholipid (PubMed:11790796, PubMed:25727495). Has high activity with 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC), catalyzing the transfer of oleic acid to N-acetyl-sphingosine. Required for normal phospholipid degradation in alveolar and peritoneal macrophages and in spleen (By similarity). May have weak lysophospholipase activity (PubMed:10092508).

Sample type

Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.

Precision

Precision (repeatability) is calculated from linearized NPX values over LOD.

Within run precision Coefficient of Variation (CV)
5%

Analytical measuring range

The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.

LOD (NPX)
-3.9
Hooked
Yes
Hook (NPX)
4.9

Dilution factor

For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.

Dilution factor
1:10