Explore HT
Gene
SLC19A1
Uniprot
P41440
Protein
Reduced folate transporter
See alternative names Cyclic dinucleotide:anion antiporter SLC19A1,
Folate:anion antiporter SLC19A1,
Intestinal folate carrier 1,
Placental folate transporter,
Reduced folate carrier protein,
Reduced folate transporter 1,
Solute carrier family 19 member 1
Uniprot Function Description
Antiporter that mediates the import of reduced folates or a subset of cyclic dinucleotides, driven by the export of organic anions (PubMed:7826387, PubMed:9041240, PubMed:10787414, PubMed:15337749, PubMed:16115875, PubMed:22554803, PubMed:31511694, PubMed:31126740, PubMed:32276275). Mechanistically, acts as a secondary active transporter, which exports intracellular organic anions down their concentration gradients to facilitate the uptake of its substrates (PubMed:22554803, PubMed:31511694, PubMed:31126740). Has high affinity for N5-methyltetrahydrofolate, the predominant circulating form of folate (PubMed:10787414, PubMed:14609557, PubMed:22554803). Also able to mediate the import of antifolate drug methotrexate (PubMed:7615551, PubMed:7641195, PubMed:9767079, PubMed:22554803). Also acts as an importer of immunoreactive cyclic dinucleotides, such as cyclic GMP-AMP (2'-3'-cGAMP), an immune messenger produced in response to DNA virus in the cytosol, and its linkage isomer 3'-3'-cGAMP, thus playing a role in triggering larger immune responses (PubMed:31511694, PubMed:31126740). 5-amino-4-imidazolecarboxamide riboside (AICAR), when phosphorylated to AICAR monophosphate, can serve as an organic anion for antiporter activity (PubMed:22554803).
Sample type
Recommended sample types are human plasma and serum. For other sample types e.g cerebrospinal fluid, (CSF), tissue or cell lysate, please contact support@olink.com for more information. Please note that protein expression levels are expected to vary in different sample types and certain assays may be affected by interfering substances such as hemolysate.
Precision
Precision (repeatability) is calculated from linearized NPX values over LOD.
Analytical measuring range
The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen.
Dilution factor
For optimal assay readout, Olink assays are run using different dilutions of the original samples e.g. undiluted, 1:10, or higher. The dilution factor for this assay is noted below and should be taken into account when estimating the appropriate addressable biological concentration of the protein based on the in vitro validation data.
Biomarker Validation Data
Additional validation data, as well as a more detailed description of how the Olink panels are quality controlled can be found in our Data Validation documents – go to Document download center