Target 96 Cardiovascular III
Gene
SCGB3A2
Uniprot
Q96PL1
Protein
Secretoglobin family 3A member 2
See alternative names Pneumo secretory protein 1,
Uteroglobin-related protein 1
Uniprot Function Description
Secreted cytokine-like protein (PubMed:12847263). Binds to the scavenger receptor MARCO (PubMed:12847263). Can also bind to pathogens including the Gram-positive bacterium L.monocytogenes, the Gram-negative bacterium P.aeruginosa, and yeast (PubMed:12847263). Strongly inhibits phospholipase A2 (PLA2G1B) activity (PubMed:24213919). Seems to have anti-inflammatory effects in respiratory epithelium (By similarity). Also has anti-fibrotic activity in lung (PubMed:24213919). May play a role in fetal lung development and maturation (PubMed:24213919). Promotes branching morphogenesis during early stages of lung development (PubMed:24213919). In the pituitary, may inhibit production of follicle-stimulating hormone (FSH) and luteinizing hormone (LH) (By similarity).
Sample type
Recommended sample types are EDTA plasma and serum. A range of additional sample types are compatible with the technology (PEA), including citrate plasma, heparin plasma, cerebrospinal fluid, (CSF), tissue and cell lysates, fine needle biopsies, microdialysis fluid, cell culture media, dried blood spots, synovial fluid, saliva, plaque extract and microvesicles. Please note that protein expression levels are expected to vary in different sample types. Certain assays are differentially affected by interfering substances such as hemolysate. Download any of our Data Validation documents or contact support@olink.com for more information.
Precision
Precision (repeatability) is calculated from linearized NPX values over LOD.
Analytical measuring range
The technical data reported below refers to the measured value in the in vitro validation assays run using known concentrations of recombinant antigen. Please note that these figures are for reference only and CANNOT be used to convert NPX values to absolute concentrations for proteins measured in plasma or serum samples.
Sensitivity plot
The calibrator curve shown below visualizes the analytical measuring range data based on in vitro measurement of recombinant antigen. Please note that this is shown for reference only and CANNOT be used to convert NPX values to absolute concentrations for proteins measured in plasma or serum samples. The vertical dotted lines represent LLOQ and ULOQ respectively, and the horizontal line indicates the LOD.
Biomarker Validation Data
Additional validation data, as well as a more detailed description of how the Olink panels are quality controlled can be found in our Data Validation documents – go to Document download center